Replace the faulty spark electrode with the help of a professional. He stated that a new thermostat/natural gas control was needed. Here the pilot knob might be stuck in one position and which is why this error is blinking. Free shipping for many products! Test the continuity of the elements. Homeguideinfo.com is a participant with Amazon and other Affiliate networks. $120.00. What Are Other Problems Common With the Rheem Water Heater? You must unclog the pilot tube to fix this issue. The Rheem PROTECH Gas Control Replacement Kit contains everything that you need to replace the Gas Valve on your Rheem gas water heater. Some of the common Problems to look out for include the following. Anyway, your water heater igniter may fail due to any of the following reasons: To troubleshoot the igniter issue, follow the ways below: Cleaning & replacing the broken igniter will be easy as long as you will follow the below DIY methods: First, unplug the water and shut off the gas supply. Picture 1 of 5. Get free shipping on qualified Gas Valve Water Heater Accessories products or Buy Online Pick Up in Store today in the Plumbing Department. Sold by enriceshop and ships from Amazon Fulfillment. Slowly pull and twist the old thermocouple from its mounting bracket. Then, place the other end of the hose to the closest floor drain. Total price: This item: Rheem SP20303D Water Heater Gas Control (Thermostat) NG. If the thermocouple fails, it wont sense the flame, interrupting the ignition system. Use the pipe wrench again to tighten up the gas valve. This is What An Energy Saver Do On A Samsung Refrigerator! You must enable JavaScript to use craigslist. If the spark is weak or there is no spark at all, there could be any of the following reasons: Follow the below methods to test the igniter and to verify the spark at the igniter: First up, turn off the gas supply. First, unplug the appliance and turn off the gas valve. So far the options to 'fix' this problem are to 1) crack my attic door open to allow cold air to circulate with the hot air in the attic, 2) put a fan in the attic to keep it circulating, or 3) have attic efficiency techs come out and make my attic more efficient (and cooler) to prevent this. Find many great new & used options and get the best deals for Rheem Natural Gas Water Heater Burner And Gas Valve WV8840C1605 at the best online prices at eBay! All you have to do is follow the simple steps below. There are some major reasons behind gas valve faults, for instance: Obstructed venting Clogged or damaged burner parts Blocked TRD A faulty thermocouple A defective gas valve Have the thermostat on your water heater adjusted downward (with a gas storage water heater you can do this yourself). Then, clean the scale deposits and debris from the burner assembly and its parts. 1. Take the new igniter and align it to the connection point. Unfortunately, youll have to replace the device if this is the case. Generally, Rheem has excellent prestige for producing credible water heaters, making them a go-to brand for most customers. Rheem Natural Gas Water Heater Burner And . Check the reset button of the upper thermostat. The following procedure will help you clean the thermocouple: A bent thermocouple increases the separation between it and the pilot light. This triggers the 9-blinking error. How To Tell If Rheem Water Heater Gas Valve Is At Problem? You can check out this video if you dont know how to test the thermopile: A functional thermopile should give between 650 to 850 millivolts. Fortunately, we broke down the way of changing it. However, the pilot light is responsible for igniting the gas channeled into your Rheem heater for warming up water. . Detach the grommet, and push the wire through the burner cover. Recently, Rheem admitted that some of her home water heaters manufactured in 2020 and 2021 have impaired gas control valves. Contact a professional if you are mechanically inclined. Rheem PROTECH. And why cant the problem be accessed before sending the gas valve. Now, open the drain valve and drain the water. Allow the thermocouple to cool down for approximately 30 minutes to 1 hour. We depend on hot water for various activities ranging from bathing, cleaning, and cooking and for use with other types of equipment. If the igniter does not get the voltage needed, you need to replace the defective igniter. Therefore, once your gas valve is faulty, you are expected to replace it entirely. Glitches in the power supply are the root reason behind the electric water heater not heating. $65.00 + $11.45 shipping. How to Convert Gas Water Heater to Electric Everything You, 5 Reasons Water Heater Pop-Off Valve Keeps Popping + Fixes, Rinnai Tankless Water Heater Control Panel Not Working -, Whirlpool Washer Control Lock Won't Turn Off - Fixed, Whirlpool Duet Dryer No Power To Control Panel (Causes +, [Fixed] Rheem Tankless Water Heater Code 12, Hot Water Heater Calcium Removal [How to Guide], Samsung Washer SUD Code but no SUDs? Find many great new & used options and get the best deals for 37E73A316P1 AP13845A-1 OEM water heater natural gas valve of water heater at the best online prices at eBay! The WT8840 water heater control from Resideo is designed for use in standing pilot applications using an immersion well for water temperature sensing. The gas valve mainly controls the gas flow to the unit andallows the pilot to be ignited. Refresh your browser window to try again. If so, it shuts off the gas supply. When this happens, it shows up as a 'Gas Control Valve Failure'. The gas valve kit ensures the safe and reliable operation of your gas water heater. Turn the pilot knob to the OFF position. But in the case of resistance changes, replace the defective chamber sensor. However, it is worth noting that, just like most appliances, your Rheem water heater will experience hitches at some point. Turn off the gas supply at first. The heaters had a space between the burner flange and the combustion chamber, which could cause a fire explosion. Also, check the connectors for physical damage. Replace the cracked hose. For safety, always cut off the gas supply before performing any maintenance on your water heater. It signals the gas valve whether the valve needs to release or terminate the gas supply. Remove the burner access cover and disconnect all the wiring connections to the control valve. The ignition lockout error occurs mainly from the failed burner ignition after 3 successive trials. Since repairing a failed control valve only serves as a short-term solution, its best to replace it with a new one. There are moments when you will find the pressure relief valve leaking. - eBay Money Back Guarantee - opens in a new window or tab, - for PayPal Credit, opens in a new window or tab, about earning points with eBay Mastercard, Report this item - opens in new window or tab. Rheem Water Heater 8 Flashes Then 1: What Does It Mean? Gas coming from the controller travels through the flex tube. Anyway, if anyhow, the combustion gasses fail to move out through the vents, the ignition process interrupts and will lead to the ignition lockout. The sensor is an essential part of the heater ignition system. Here, the high limit switch gets trippeddue to increasing water temperature to an unsafe level and turns the heater into high-temperature mode. The control knob is in the pilot position, and the light stays lit. The chamber sensor is an important safety element that converts the heat from a burning flame into a small electrical current. Then, detach the gas line from the gas valve. Inspect the pressure relief valve, and clean specks of dirt blocked into it. Clean the element first. Now, set the gas control to pilot and hold down the gas control knob. The heater might stop functioning until you resolve the error. Shop products from small business brands sold in Amazons store. The gas control valve in a water heater is used to regulate the gas flow. If you find the reading below 400, be sure the element is defective. Rusted or damaged burner ground is the root one among them. To fix the issue, inspect the flex tube for cracks or blockages and clean it if necessary. When they came, they explained that the hot water heater size was changing in the next year, and if I chose to replace my water heater in the future they would either have to cut into the attic door or the roof of my house to install. Also, clean the build-up dirt or debris from the power vent. Is There a Recall on Rheem Gas Water Heaters? White-Rodgers 37E73A-903 Gas Water Heater Thermostat Control Intelli-Vent Valve. Now test the thermopile using a multimeter. The good news is you can easily detect a leaking gas through the smell. There are some major reasons behind gas valve faults, for instance: Follow the below guide to resolve the 7 blinking from the water heater: If your Rheem water heaters red light is blinking 8 times, it is sure that there is a false pilot signal issue in the heating system. Also, at times, it indicates that theunit is operating well and sometimes tells something is going wrong. This error tells you that the water temperature exceeds 180 degrees Fahrenheit and the heater is shutting down. Inconsistent gas supply to the burner leads to water temperature fluctuations and pilot light challenges. Collection page for Water Heater Gas Valves & Controls is loaded. Last updated on December 4th, 2022 at 08:36 am. Use the adjustable wrench to detach all the lines like the thermocouple connector and other supply lines. at the best online prices at eBay! Commonly referred to as the "T&P" valve. When I moved into my house about 9 months ago, we had to have a plumber come fix a leaky valve on the hot water heater. Improper venting is one of the major reasons for ignition failure in the water heater. Inspect the igniter and check for spark. Common Plumbing Problems That We Correct. Clean it first using sandpaper and scrub off all the dirt. How do you know you need a new hot water heater? Keep an eye out for the following to know whether your gas control valve has failed: The best way around this issue is to replace the main control valve altogether. Discover more about the small businesses partnering with Amazon and Amazons commitment to empowering them. Now, move to the thermocouple and check it electrically. First of all, do a reset on the gas control valve. Now, open the drain valve of your water heater and let the water drain. The gas valve might be clogged by fuel residue, or the damaged gas valve itself is the culprit. . . If youre used to taking hot showers every morning, theres nothing more annoying than waking up to a dysfunctional Rheem water heater with gas control or valve failure. A leaking flex tube reduces the amount of gas that reaches the burner. Can you change a gas valve on a water heater without draining it? Click to enlarge. 2. Therefore, it gets frustrating when your water heater develops any slight fault. Zoeller Sump Pump Wont Turn On [7 Easy Solutions]. Then, rotate the pipe wrench counterclockwise to pull out the gas control valve. If the element had gone bad, then you would . Temperature & Pressure Relief Valves. The gas reaches the pilot light through the pilot tube, where its ignited to heat the water. Your Rheem water heater gives you room to regulate the degree of coldness or hotness you desire your water to be. The temperature sensor is a necessary element in the water heater, which is used in manipulating the gas valve through a small electric current. Recently, Rheem admitted that some of her home water heaters manufactured in 2020 and 2021 have impaired gas control valves. If there is no issue with the thermopile and the pilot light goes out, I bet the gas valve is the culprit. Rheem water heater is in the range of the most well-known brand in the HVAC industry for producing reliable and long-lasting. And this chapter will let you learn how to replace gas control valve on Rheem water heater. The part is required anytime the cag control is damaged or needs . Once you notice fluctuations in the level of coldness or hotness of your water without you making inputs, its a good sign that theres a fault somewhere. For screen reader problems with this website, please call 1-800-430-3376 or text 38698 (standard carrier rates apply to texts) . Pull the damaged igniter from the connection. However, the flame sensor goes bad due to the following 3 major reasons: However, in this stage, we will walk you through how you will deal with the defective flame sensor: if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[250,250],'fireplacehubs_com-netboard-2','ezslot_21',116,'0','0'])};__ez_fad_position('div-gpt-ad-fireplacehubs_com-netboard-2-0');To clean or replace the faulty flame sensor, follow each of the steps described below: Step 1: First, unplug the power connection and shut off the gas shut-off valve. Just attach a garden hose to the drain valve which you can find at the bottom of the water heater. Find many great new & used options and get the best deals for Rheem PROTECH Gas Combination Control Thermostat Kit Water Heater SP21062A at the best online prices at eBay! COPYRIGHT 2023. Keep scrolling! $75.00. Improper alignment of the ignition control. Is as advertised. Also, due to the inter-purge duration, the system is being purged. $30.00 + $15.02 shipping. The water heater needs a fresh air supply for combustion and to continue the ignition systems properly. If the heaters red light blinks for 1 time, that is a sign of the normal operation, and there is nothing significant to do. If not, the thermocouple is broken and needs replacing. Otherwise, when the thermocouple senses the flame, it keeps the gas valve open to supply gas to the pilot light. In this guide on the Rheem water heater gas valve problem, we will break down: A bad gas valve on the Rheem water heater prevents the pilot light from coming on. Then replace the mounting screw and ensure a secured connection. The relief valve controls the amount of water discharged when turned on. I recommend you to have the gas valve replaced by yourself, which will save you the labor cost. Step 2: Remove the screws of the burner assembly and slide it out carefully. By the end, you will be able to understand the workings of the appliance and how to test and reset a terrible gas valve problem. When this happens, the thermocouple will not sense heat to keep the gas valve open. Check the main supply tube and pilot supply tube at the gas control valve for gas leaks by using a soap-and-water solution. Free shipping for many products! $6.92.